Summary: | app-antivirus/clamav-0.99.2-r1 check_bytecode.c:127:F:arithmetic:test_inflate_jit:0: cli_bytecode_run failed, expected: 0, have: 28 | ||
---|---|---|---|
Product: | Gentoo Linux | Reporter: | ernsteiswuerfel <erhard_f> |
Component: | Current packages | Assignee: | Antivirus Team <antivirus> |
Status: | RESOLVED FIXED | ||
Severity: | normal | CC: | net-mail+disabled, whissi |
Priority: | Normal | Keywords: | TESTFAILURE |
Version: | unspecified | ||
Hardware: | PPC | ||
OS: | Linux | ||
URL: | https://bugzilla.clamav.net/show_bug.cgi?id=12024 | ||
Whiteboard: | |||
Package list: | Runtime testing required: | --- | |
Attachments: |
emerge --info
build.log test-suite.log build.log (clamav-0.99.4) test-suite.log (clamav-0.99.4) |
Created attachment 498480 [details]
build.log
Created attachment 498482 [details]
test-suite.log
Same failure for app-antivirus/clamav-0.99.4. Looks like this issue is already upstream (for AIX): https://bugzilla.clamav.net/show_bug.cgi?id=12024 Created attachment 524612 [details]
build.log (clamav-0.99.4)
Created attachment 524614 [details]
test-suite.log (clamav-0.99.4)
Please re-test with =app-antivirus/clamav-0.99.4-r1. I can confirm =app-antivirus/clamav-0.99.4-r1 passes all the tests. Thanks! |
Created attachment 498478 [details] emerge --info One of the tests causes a segfault on my system: check_bytecode.c:127:F:arithmetic:test_inflate_jit:0: cli_bytecode_run failed, expected: 0, have: 28 check_bytecode.c:108:E:arithmetic:test_inflate_int:0: (after this point) Received signal 11 (Segmentation fault) NOTICE: Use the 'T' environment variable to adjust testcase timeout