Go to:
Gentoo Home
Documentation
Forums
Lists
Bugs
Planet
Store
Wiki
Get Gentoo!
Gentoo's Bugzilla – Attachment 290609 Details for
Bug 364485
sys-libs/freeipmi-1.0.8 stable request || sys-libs/freeipmi-0.8.9 de-keywording request
Home
|
New
–
[Ex]
|
Browse
|
Search
|
Privacy Policy
|
[?]
|
Reports
|
Requests
|
Help
|
New Account
|
Log In
[x]
|
Forgot Password
Login:
[x]
ipmi-sensors-config --checkout
ipmi-sensors-config (text/plain), 5.55 KB, created by
Michael Mair-Keimberger (iamnr3)
on 2011-10-23 09:04:48 UTC
(
hide
)
Description:
ipmi-sensors-config --checkout
Filename:
MIME Type:
Creator:
Michael Mair-Keimberger (iamnr3)
Created:
2011-10-23 09:04:48 UTC
Size:
5.55 KB
patch
obsolete
># ipmi-sensors-config --checkout >Section 1_BB_+1.1V_Vtt > ## Possible values: Yes/No > Enable_All_Event_Messages Yes > ## Possible values: Yes/No > Enable_Scanning_On_This_Sensor Yes > ## Give valid input for sensor type = Voltage; units = Volts > Lower_Non_Critical_Threshold 1.033200 > ## Give valid input for sensor type = Voltage; units = Volts > Lower_Critical_Threshold 1.008000 > ## Give valid input for sensor type = Voltage; units = Volts > Upper_Non_Critical_Threshold 1.178100 > ## Give valid input for sensor type = Voltage; units = Volts > Upper_Critical_Threshold 1.209600 > ## Give valid input for sensor type = Voltage; units = Volts; 'None' to not use hysteresis > Positive_Going_Threshold_Hysteresis 0.006300 > ## Give valid input for sensor type = Voltage; units = Volts; 'None' to not use hysteresis > Negative_Going_Threshold_Hysteresis 0.006300 >EndSection >Section 2_BB_+1.5V_AUX > ## Possible values: Yes/No > Enable_All_Event_Messages Yes > ## Possible values: Yes/No > Enable_Scanning_On_This_Sensor Yes > ## Give valid input for sensor type = Voltage; units = Volts > Lower_Non_Critical_Threshold 1.372800 > ## Give valid input for sensor type = Voltage; units = Volts > Lower_Critical_Threshold 1.333800 > ## Give valid input for sensor type = Voltage; units = Volts > Upper_Non_Critical_Threshold 1.622400 > ## Give valid input for sensor type = Voltage; units = Volts > Upper_Critical_Threshold 1.669200 > ## Give valid input for sensor type = Voltage; units = Volts; 'None' to not use hysteresis > Positive_Going_Threshold_Hysteresis None > ## Give valid input for sensor type = Voltage; units = Volts; 'None' to not use hysteresis > Negative_Going_Threshold_Hysteresis None >EndSection >Section 3_BB_+1.5V > ## Possible values: Yes/No > Enable_All_Event_Messages Yes > ## Possible values: Yes/No > Enable_Scanning_On_This_Sensor Yes > ## Give valid input for sensor type = Voltage; units = Volts > Lower_Non_Critical_Threshold 1.365000 > ## Give valid input for sensor type = Voltage; units = Volts > Lower_Critical_Threshold 1.326000 > ## Give valid input for sensor type = Voltage; units = Volts > Upper_Non_Critical_Threshold 1.625000 > ## Give valid input for sensor type = Voltage; units = Volts > Upper_Critical_Threshold 1.677000 > ## Give valid input for sensor type = Voltage; units = Volts; 'None' to not use hysteresis > Positive_Going_Threshold_Hysteresis 0.013000 > ## Give valid input for sensor type = Voltage; units = Volts; 'None' to not use hysteresis > Negative_Going_Threshold_Hysteresis 0.013000 >EndSection >Section 4_BB_+1.8V > ## Possible values: Yes/No > Enable_All_Event_Messages Yes > ## Possible values: Yes/No > Enable_Scanning_On_This_Sensor Yes > ## Give valid input for sensor type = Voltage; units = Volts > Lower_Non_Critical_Threshold 1.689200 > ## Give valid input for sensor type = Voltage; units = Volts > Lower_Critical_Threshold 1.637700 > ## Give valid input for sensor type = Voltage; units = Volts > Upper_Non_Critical_Threshold 1.926100 > ## Give valid input for sensor type = Voltage; units = Volts > Upper_Critical_Threshold 1.987900 > ## Give valid input for sensor type = Voltage; units = Volts; 'None' to not use hysteresis > Positive_Going_Threshold_Hysteresis None > ## Give valid input for sensor type = Voltage; units = Volts; 'None' to not use hysteresis > Negative_Going_Threshold_Hysteresis None >EndSection >Section 5_BB_+3.3V > ## Possible values: Yes/No > Enable_All_Event_Messages Yes > ## Possible values: Yes/No > Enable_Scanning_On_This_Sensor Yes > ## Give valid input for sensor type = Voltage; units = Volts > Lower_Non_Critical_Threshold 3.027200
You cannot view the attachment while viewing its details because your browser does not support IFRAMEs.
View the attachment on a separate page
.
View Attachment As Raw
Actions:
View
Attachments on
bug 364485
:
290603
|
290605
|
290607
| 290609