Gentoo Websites Logo
Go to: Gentoo Home Documentation Forums Lists Bugs Planet Store Wiki Get Gentoo!
Bug 422167 - Please stabilize =sys-apps/cciss_vol_status-1.09-r1
Summary: Please stabilize =sys-apps/cciss_vol_status-1.09-r1
Status: RESOLVED FIXED
Alias: None
Product: Gentoo Linux
Classification: Unclassified
Component: [OLD] Keywording and Stabilization (show other bugs)
Hardware: All Linux
: Normal enhancement (vote)
Assignee: Tony Vroon (RETIRED)
URL: http://packages.gentoo.org/package/sy...
Whiteboard:
Keywords: STABLEREQ
Depends on:
Blocks:
 
Reported: 2012-06-19 17:42 UTC by Paweł Hajdan, Jr. (RETIRED)
Modified: 2012-06-20 14:42 UTC (History)
2 users (show)

See Also:
Package list:
Runtime testing required: ---


Attachments

Note You need to log in before you can comment on or make changes to this bug.
Description Paweł Hajdan, Jr. (RETIRED) gentoo-dev 2012-06-19 17:42:27 UTC
Is it OK to stabilize =sys-apps/cciss_vol_status-1.09-r1 ?

If so, please CC all arches which have stable keywords

for older versions of this package and add STABLEREQ keyword

to the bug.
Comment 1 Tony Vroon (RETIRED) gentoo-dev 2012-06-19 19:29:51 UTC
Agreed, with robbat2's fix this is viable for stable. Arches, please compile test and mark stable:
=sys-apps/cciss_vol_status-1.09-r1

Could the last arch please remove:
=sys-apps/cciss_vol_status-1.03
=sys-apps/cciss_vol_status-1.09

Without hardware, the output from the utility will not be particularly informative. However, you should be able to confirm that the crontab entry installs and that the utility can not be crashed with command line input.
Comment 2 Michael Orlitzky gentoo-dev 2012-06-20 00:44:14 UTC
I have also confirmed that the cron jobs work in both cases.

x86, all drives OK
-------------------
# cciss_vol_status /dev/cciss/c0d0
/dev/cciss/c0d0: (Smart Array 5i) RAID 5 Volume 0 status: OK.   At least one spare drive designated.  At least one spare drive remains available.
/dev/cciss/c0d0: (Smart Array 5i) Enclosure  (S/N: #) on Bus 1, Physical Port J2 status: OK.


amd64, one drive failed
-----------------------
# cciss_vol_status /dev/cciss/c0d0
/dev/cciss/c0d0: (Smart Array P400) RAID 1 Volume 0 status: OK.   At least one spare drive designated.  At least one activated on-line spare drive is completely rebuilt on this logical drive.  At least one spare drive activated.
  Failed drives:
         connector 2I box 1 bay 3                 HP      DG146ABAB4                           3NM2LR9D00009802006S     HPDE

  Drives currently substituted for by spares:
         connector 1I box 1 bay 7                 HP      EG0146FAWHU                          6SD05XZ20000B03927DF     HPDE

    Total of 1 failed physical drives detected on this logical drive.
Comment 3 Jeff (JD) Horelick (RETIRED) gentoo-dev 2012-06-20 06:02:03 UTC
x86 stable. Thanks Michael.
Comment 4 Agostino Sarubbo gentoo-dev 2012-06-20 14:42:37 UTC
amd64 stable. Last arch, closing