Bug 371721 - media-gfx/dispcalgui-0.7.0.7 - measurements impossible
Summary: media-gfx/dispcalgui-0.7.0.7 - measurements impossible
Status: RESOLVED INVALID
Alias: None
Product: Gentoo Linux
Classification: Unclassified
Component: Current packages (show other bugs)
Hardware: All Linux
: Normal minor (vote)
Assignee: Markos Chandras (RETIRED)
URL: http://hoech.net/dispcalGUI/
Whiteboard:
Keywords:
Depends on:
Blocks:
 
Reported: 2011-06-15 09:19 UTC by ymi
Modified: 2011-06-20 12:44 UTC (History)
1 user (show)

See Also:
Package list:
Runtime testing required: ---


Attachments

Note You need to log in before you can comment on or make changes to this bug.
Description ymi 2011-06-15 09:19:21 UTC
Hi,
I installed dispcal-0.7.0.7 that seems to work except that the buttons for calibration and caracterisation are greyed and do not operate.
It happens that the author Florian Höch announced a bug on june 5 in this version dated 2011-05-29 (see http://hoech.net/dispcalGUI/). The bug has been corrected in the source (with same version nb) but I don't know if it has been modified in the gentoo version.
I'm not sure if it is the reason of my pb though. I couldn't test an earlier version since none is available in Gentoo. Maybe I got something wrong in my setup.

Reproducible: Always

Steps to Reproduce:
1. Install dispcal-0.7.0.7
2. Setup. Activate sensor : OK.
3. Specify path to Argyllcms binaries
Actual Results:  
Calibration and caracterization buttons are not working (greyed).

Expected Results:  
Calibration and caracterization buttons are working (not greyed).
Comment 1 Marios Andreopoulos 2011-06-15 13:01:35 UTC
For me it worked fine but just in case, I removed the source archive ( rm /usr/portage/distfiles/dispcalGUI-0.7.0.7.tar.gz ) from my computer, re-emerged dispcalgui and it still works as expected.

Usually when the calibration / profile buttons are grayed out, it means that your calibration device hasn't been detected.

In the Instrument/Port field, does it have your calibration device or is it empty?
Comment 2 ymi 2011-06-17 14:15:54 UTC
If I well remember, I had activated the sensor and the Instrument/Port field was showing the Spyder2 but the buttons were greyed. But today I tried again and the buttons are activated. I don't know what I did different (maybe a differrent usb port). However the measurement is still not possible, the console shows "Setting up the instrument" for a while and then displays these two messages "dispcal: Error - new_disprd() failed with instrument Access Failed" and "The calibration has not been finished"

I also tried on my previous computer that is running Gentoo and dispcalGUI-0.6.2.2 : I emerged version dispcalGUI-0.7.0.7 and it works correctly. 

The problem I encounter is on my new computer and is probably related to some wrong settings. So I should probably close this bug item.

ymi
Comment 3 Marios Andreopoulos 2011-06-17 15:04:24 UTC
Try to disconnect any other USB devices from your computer. I've found out that some can cause trouble to my colorimeter during the measurements.

Also for Spyder 2 there is a special option in the tools menu (though I think you already know that).


I have an Eye One Display 2 and although I have tested it and works fine in 5 PCs, there is 1 PC that no matter what, it won't work, neither in Linux nor in Windows. Dispcalgui will always give an error about accessing it with this PC.
Comment 4 ymi 2011-06-20 12:43:23 UTC
 
yes, I knew this option and I also tried all possible configurations with the usb ports. It is really a problem with usb and Spyder2 as reported in several other posts I found. For me, on my new laptop (dell XPS L501x) it works only on Windows with the proprietary software but not with argyllcms neither on Linux nor Windows.
Thanks for your help.
I will close this bug item as it is not related to dispcalgui itself but for info here are some of the error messages that shows in the log window :
..
Setting up the instrument
usb_get_paths about to look through devices:
usb_check_and_add() called with VID 0x1d6b, PID 0x2
usb_check_and_add() called with VID 0x1d6b, PID 0x2
usb_check_and_add() called with VID 0x1d6b, PID 0x3
usb_check_and_add() called with VID 0x8087, PID 0x20
usb_check_and_add() called with VID 0x8087, PID 0x20
usb_check_and_add() called with VID 0x408, PID 0x2fb1
usb_check_and_add() called with VID 0x85c, PID 0x200
usb_check_and_add() found known instrument
failed to open serial "/dev/ttyS3"
failed to open serial "/dev/ttyS2"
failed to open serial "/dev/ttyS1"
failed to open serial "/dev/ttyS0"
spyd2: About to init coms
spyd2: About to init USB
icoms: About to set usb port characteristics
icoms: About to open the USB port, tries 0
icoms: USB port needs opening
icoms: About to open USB port 'usb:/bus3/dev2/ (ColorVision Spyder2)'
icoms: USB port is now open
icoms: Clearing any USB errors
icoms: usb port characteristics set ok
spyd2: init coms has suceeded
spyd2: About to init instrument

spyd2: Instrument reset
Reset complete, ICOM code 0x0

spyd2: Get Status
Get Status returns 3 ICOM err 0x0

spyd2: Get Status
Get Status returns 1 ICOM err 0x0
spyd2: about to read all the EEProm values

spyd2: Read EEProm addr 5, bytes 2
Read EEProm ICOM err 0x0
hwver = 0x307

spyd2: Read EEProm addr 8, bytes 8
Read EEProm ICOM err 0x0
serno = '00760698'

spyd2: Read EEProm addr 16, bytes 108
Read EEProm ICOM err 0x0
... snip.....
pyd2: Read EEProm addr 372, bytes 4
Read EEProm ICOM err 0x0
Cal_A:
Cal_A [0][0][0] = 0.000000
Cal_A [0][0][1] = 0.000000
Cal_A [0][0][2] = 0.013071
...snip...
al_F [6] = 0.002193

spyd2: all EEProm read OK
spyd2: about to download the PLD pattern

spyd2: Load PLD 8 bytes
Load PLD returns ICOM err 0x0
...snip...
spyd2: Load PLD 8 bytes
Load PLD returns ICOM err 0x0

spyd2: Get Status
Get Status returns 0 ICOM err 0x0
spyd2: PLD pattern downloaded

spyd2: Get Reading, clocks = 500, minfc = 0, maxfc = 0
Trigger Get Reading returns ICOM code 0x0

spyd2: Get Reading retry with ICOM err 0x2000

spyd2: Resetting end point
Trigger Get Reading returns ICOM code 0x0
Get Reading Stat retry with ICOM err 0x2000
...aborted.
Calibration has not been finished.