Summary: | mm-sources-2.6.2-r1 incorrect sensors output (lm_sensors) | ||
---|---|---|---|
Product: | Gentoo Linux | Reporter: | Nicolas Laplante <nicolas-laplante> |
Component: | [OLD] Core system | Assignee: | x86-kernel (DEPRECATED) <x86-kernel> |
Status: | RESOLVED INVALID | ||
Severity: | normal | ||
Priority: | High | ||
Version: | 1.4 | ||
Hardware: | x86 | ||
OS: | Linux | ||
Whiteboard: | |||
Package list: | Runtime testing required: | --- |
Description
Nicolas Laplante
2004-02-09 14:28:41 UTC
I just upgraded my kernel to 2.6.2-mm1. I already have the masked lm_sensors package which works with kernel 2.6. When I type "sensors", I get the following output: w83697hf-isa-0290 Adapter: ISA adapter Algorithm: ISA algorithm VCore: +1.76 V (min = +1.71 V, max = +1.89 V) +3.3V: +3.26 V (min = +3.14 V, max = +3.46 V) +5V: +4.84 V (min = +4.73 V, max = +5.24 V) ALARM +12V: +12.10 V (min = +10.82 V, max = +13.19 V) -12V: -11.95 V (min = -13.18 V, max = -10.88 V) -5V: -5.20 V (min = -5.25 V, max = -4.75 V) V5SB: +5.46 V (min = +4.73 V, max = +5.24 V) VBat: +3.34 V (min = +2.40 V, max = +3.60 V) fan1: 0 RPM (min = 2824 RPM, div = 2) fan2: 0 RPM (min = 3139 RPM, div = 2) temp1: +370°C (high = +700°C, hyst = +650°C) sensor = thermistor temp2: +335.0°C (high = +700°C, hyst = +670°C) sensor = thermistor alarms: beep_enable: Sound alarm disabled The temperatures in temp1 and temp2 are incorrect. They are multiplicated by 10. The kernel 2.6.1 (gentoo-dev-sources) doesn't show this problem. Yep, you should be using lm-sensors-2.8.3.20040202 or lm-sensors-2.8.4 for 2.6.2, which is now in Portage as stated on the lm_sensors website. Thanks. |