Description Frederic Mangeant 2006-01-13 08:51:53 UTC
The addition of the "diskio" module would be very useful, as it allows to get useful statistics like this :

snmptable -v 2c -c community host diskIOTable           
SNMP table: UCD-DISKIO-MIB::diskIOTable

 diskIOIndex diskIODevice diskIONRead diskIONWritten diskIOReads diskIOWrites diskIOLA1 diskIOLA5 diskIOLA15
           1          ad0  3136086528     1329497088    12031712     18256151         2         6          6
           2          ad1   152385536       35630080     6365960      8081515         0         0          0
           3         acd0           0              0           0            0         0         0          0
           4          sa0           0              0           0            0         0         0          0
           5          fd0           0              0           0            0         0         0          0
           6        pass0           0              0           0            0         0         0          0
           7          md0           0              0           0            0         0         0          0 


I've just modified the ebuild to read :

mibs="host ucd-snmp/dlmod ucd-snmp/diskio"

instead of

mibs="host ucd-snmp/dlmod"

Tested with net-snmp-5.2.1.2-r1, it works fine.
Comment 1 Benjamin Smee (strerror) (RETIRED) gentoo-dev 2006-01-13 09:49:13 UTC
check 5.3, i added it a while back.