Go to:
Gentoo Home
Documentation
Forums
Lists
Bugs
Planet
Store
Wiki
Get Gentoo!
Gentoo's Bugzilla – Attachment 837245 Details for
Bug 883171
dev-lang/gnucobol-3.1.2 fails tests
Home
|
New
–
[Ex]
|
Browse
|
Search
|
Privacy Policy
|
[?]
|
Reports
|
Requests
|
Help
|
New Account
|
Log In
[x]
|
Forgot Password
Login:
[x]
4-testsuite.log
4-testsuite.log (text/plain), 1.62 KB, created by
Agostino Sarubbo
on 2022-11-26 17:37:46 UTC
(
hide
)
Description:
4-testsuite.log
Filename:
MIME Type:
Creator:
Agostino Sarubbo
Created:
2022-11-26 17:37:46 UTC
Size:
1.62 KB
patch
obsolete
># -*- compilation -*- >962. run_extensions.at:127: testing HP COBOL octal literals ... >./run_extensions.at:180: $COMPILE -fhp-octal-literals=ok prog.cob >--- /dev/null 2022-11-24 14:49:09.707094785 +0100 >+++ /var/tmp/portage/dev-lang/gnucobol-3.1.2/work/gnucobol-3.1.2/tests/testsuite.dir/at-groups/962/stderr 2022-11-26 17:03:24.425721277 +0100 >@@ -0,0 +1,14 @@ >+prog.cob:7: warning: handling of HP COBOL octal literals is unfinished; implementation is likely to be changed >+prog.cob:9: warning: handling of HP COBOL octal literals is unfinished; implementation is likely to be changed >+prog.cob:11: warning: handling of HP COBOL octal literals is unfinished; implementation is likely to be changed >+prog.cob:7: warning: alphanumeric value is expected >+prog.cob:11: warning: value size exceeds data size >+prog.cob:14: warning: handling of HP COBOL octal literals is unfinished; implementation is likely to be changed >+prog.cob:26: warning: handling of HP COBOL octal literals is unfinished; implementation is likely to be changed >+prog.cob:31: warning: handling of HP COBOL octal literals is unfinished; implementation is likely to be changed >+prog.cob:31: warning: value size exceeds data size >+prog.cob:31: note: value is 12594 >+prog.cob:11: note: 'ITEM-NUM' defined here as PIC 99 >+prog.cob:36: warning: handling of HP COBOL octal literals is unfinished; implementation is likely to be changed >+prog.cob:36: warning: alphanumeric value is expected >+prog.cob:7: note: 'ITEM-ALPHA' defined here as PIC XX >962. run_extensions.at:127: 962. HP COBOL octal literals (run_extensions.at:127): expected failure (run_extensions.at:180)
You cannot view the attachment while viewing its details because your browser does not support IFRAMEs.
View the attachment on a separate page
.
View Attachment As Raw
Actions:
View
Attachments on
bug 883171
:
837205
|
837207
|
837209
|
837211
|
837213
|
837215
|
837217
|
837219
|
837221
|
837223
|
837225
|
837227
|
837229
|
837231
|
837233
|
837235
|
837237
|
837239
|
837241
|
837243
| 837245